2 Watt Cooled PbS Detectors can extend the wavelength range of detectable gases, increase signals, and improve the detection rate and signal-to-noise ratio of the PbS detector.
2 Watt Cooled PbS Detectors is also an ideal choice for applications in temperature changing environments, as by adjusting the TEC current, the temperature of the infrared detector element can be maintained stable, reducing the detection signal drift caused by temperature changes.
Supplier:Infrared Materials
Package: TO-37, TO-8
Brand Introduction:
Infrared Materials Incorporated is a manufacturer of high performance Lead Sulfide (PbS) and Lead Selenide (PbSe) IR detectors and array components, sensitive in the IR spectral range of 1– 5.5 microns. PbS and PbSe detectors are commonly used as the critical sensing element in commercial process control systems, industrial gas monitors, spectroscopy, imaging, and medical CO2 gas analyzers, fire & spark detection systems, combustion control systems, moisture analyzers, and flash detection systems.
Infrared Materials has extensive experience in building drop-in replacement assemblies in single and multi-channel configurations to match the form, fit, and functional requirements of one-off prototype projects and production level programs. The detectors are produced in Santa Rosa, California and distributed through representatives worldwide.
Key features:
• 2 Watt TEC Cooled
• High sensitivity of 1–3.3um Wavelength
• TO-37, TO-8 Package
• Sapphire windows, specific wavelength filters, etc
Specification:
Ambient Temperature: | +25°C |
Detector Operating Temperature | -35°C |
Typical Cooler Power at or near Max. Cooling: | 0.9 volts @ 1.2 amps |
Standard Specifications – Electrical All detector specifications are at a bias voltage of 50 V/mm distance between electrodes applied across the detector and with a one MegOhm load resistor in series. All specifications apply at or near maximum cooling with the heat sink @ +25°C. | ||||
Minimum | Typical | Maximum | Units | |
Wavelength of Max. Response | 2.4 | 2.5 | µm | |
D*(λpk, 630 Hz, 1 Hz) | 1.0 x 1011 | 1.5 x 1011 | cm Hz1/2 w-1 | |
Element Resistance (Dark) | 2.0 | 3.0 | 15.0 | MegOhm |
Time Constant (not typically measured) | 1200 | 2500 | µsec | |
Rated Element Temperature | +65 | °C | ||
Delta T at or near Max. Cooling | 55 | 60 | °C |
Model Number | Element Size (mm) | Responsivity (lpk, 630) v/w | Standard Package Options | |
Minimum | Typical | |||
A1-( )C3T | 1 x 1 | 1,300,000 | 2,000,000 | TO-37, TO-8 |
A2-( )C3T | 2 x 2 | 660,000 | 1,000,000 | TO-37, TO-8 |
A3-( )C3T | 3 x 3 | 430,000 | 640,000 | TO-37, TO-8 |
Typical applications:
• NDIR Gas Sensing
• Spark detection, flame detection